Abstract

The efficiency of 4 K Stirling type pulse tube cryocoolers (SPTC) is rather low compared with that of 80 K SPTCs. Real gas effects and low specific heat capacity ratio of regenerator matrix to helium near 4 K are the main reasons that lead to the low efficiency of 4 K SPTC. A single‐stage Stirling type PTC precooled by a two‐stage G‐M type PTC is developed to study the performance of 4 K Stirling type PTC with a focus on the performance of the regenerator working at 4 K–10 K. In order to reduce loss associated with real gas effects, relatively low average pressure was used. Gd2O2S (GOS) was used as regenerator matrix to replace HoCu2 around 4 K to decrease the regenerator loss caused by ineffective heat transfer between regenerator matrix and helium. A systematic comparison between the two types of regenerator matrix was made theoretically and experimentally including effect of frequency, average pressure and precooling temperature. Performance of the linear compressor is also presented in this paper.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call