Abstract

The heat loss from cavity receiver in parabolic dish system determines the efficiency and cost effectiveness of the system. A modified three coil solar cavity receiver of inner wall area approximately three times of single coil receiver, is experimentally investigated to study the effect of fluid inlet temperature (Tfi=50°C to 75 °C) and cavity inclination angle (θ = 0° to 90°) on the heat loss from receiver under wind condition for head on wind and side on wind velocity at 3 m/s. Overall it was found that the natural and forced convection total heat loss increases with increase in mean fluid temperature. The combined heat loss decreases sharply with the increase in cavity inclination and observed to be maximum for horizontal position of receiver and minimum with the receiver facing vertically downward for all investigations. The maximum heat lossin wind test (V=3m/s) is 1045 W at θ=0° cavity inclination at mean fluid temperature 68 °C and minimum at 173 W θ=90° at 53°C. Total heat loss from the receiver under wind condition (V=3m/s) is up to 25% higher(1.25 times at 0° inclination) than without wind at mean fluid temperature ~70°C and minimum 19.64 % (1.2 times at 90° inclination) in mean temperature ~50 °C . In horizontal position of the receiver (θ=0°), the totalheat loss by head on wind is about 1.23 times (18% higher ) as compared to side on wind (at fluid mean temperature ~ 70°C). For receiver facing downward (θ=90°), for head-on wind, total heat loss is approximately the same as that for side-on wind.

Highlights

  • The parabolic dish-receiver assembly is suitable for supplying heat for process applications as well as generating power

  • The objective of this work is to study the effect of the fluid inlet temperature (TT ) and cavity inclination (θ) on heat loss from three coil cavity receiver under head on wind and side on wind at 3 m/sec

  • The forced convection heat loss decreases with the increase of cavity inclination angle when mean fluid temperature is constant; this may be because with the increasing inclination flow of hot air from inside of the cavity is difficult

Read more

Summary

Introduction

The parabolic dish-receiver assembly is suitable for supplying heat for process applications as well as generating power. It consists of a paraboloid dish with downward facing receiver at the focus. A cavity receiver is used to capture the flux at focus since it has low heat loss (Harris and Lenz) [1]. Natural convection heat loss from solar cavity receiver is investigated by many researchers. A very few investigation are carried out with wind effects and forced convection on receiver heat loss. Wind can considerably affect the thermal performance of the cavity receiver

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call