Abstract

This prospective study evaluated the marginal bone level and periodontal parameters 6 years after placement of a convergent transmucosal neck implant. In total, 71 implants were placed in 60 patients. Of these, 52 implants were placed with a flapless technique and with the convergent neck exposed by 1 mm (early and delayed placement), while 19 implants were placed immediately after extraction (immediate placement). At least 3 months after insertion, customized abutments were applied and provisional resin crowns were cemented, while being careful to prevent any tissue compression. After 3 weeks, definitive metal-ceramic crowns were designed with the finish line at the soft tissue level and free from any compression. The implant survival rate at 6 years, marginal bone level changes (ΔMBL, mm), and Pink Esthetic Score (PES) were evaluated. Gingival phenotype was determined before the implant surgeries (thin/thick). A three-level hierarchical model was examined with a random intercept and random slope on follow-up time at the patient level and a random intercept at the implant level. In all, 57 patients with 67 implants reached the 6-year point; 3 patients (5.0%) dropped out. The implant survival rate was 100%. ΔMBL from baseline to 24 months was 0.58 mm (95% CI: 0.48, 0.68), while ΔMBL from 24 to 72 months was 0.33 mm (95% CI: 0.19, 0.47). PES improved steadily from 6 to 48 months (+0.96; 95% CI: 0.71, 1.20), with overall stability at 72 months. No correlation between MBL and PES was observed. A significant association was found between thick gingival phenotype and less MBL variation. Greater implant diameter offered more MBL stability after 3 years but resulted in lower PES values. The use of convergent transmucosal neck implants placed with a flapless transmucosal approach with the crown margin positioned at the gingival level preserved marginal bone and guided gingival morphology for up to 72 months. The gingival phenotype was the parameter that most affected the soft and hard tissues. In the long term, implant placement timing was not related to MBL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.