Abstract

A method using calorimetry to measure magnet losses in pressurized Helium II is described. The isothermal nature of He II is used in measuring the overall heat capacity of the system and the net refrigeration power. During the measurements, the refrigeration power is held fixed, and the system (400 liters) temperature is near 1.92 K. The calorimetric measurement was calibrated against known power inputs between 1 and 20 W. This technique can even measure heat loads higher than the available refrigeration. Results of loss measurement on two dipole magnets are reported.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.