Abstract

Abstract Currently available methods for detecting the emissions of 55 Fe involve electroplating of the iron or preparation of samples for liquid scintillation counting. The latter technique is readily available to most laboratories; however, current methodology is complex, may be hazardous, and the samples are, not indefinitely stable. The use of benzene phosphinic acid to precipitate iron as an insoluble white compound, ferric benzene phosphinate, avoids these problems. The method described is highly reproducible and results in suitable efficiency for counting mixed samples containing 55 Fe and 59 Fe with standard liquid scintillation techniques.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.