Abstract

BackgroundVascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion.MethodsIn 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were randomised to stepwise venous occlusion, complete venous occlusion, complete arterial occlusion or controls.ResultsAll parameters were stable through baseline measurements. Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular occlusions on the vessel it was placed.ConclusionsWe developed a new model for stepwise renal venous blood flow occlusion. Furthermore, the first comparison of the implantable Doppler probe and microdialysis for detection of renal vascular occlusions was made. The implantable Doppler probe could only detect flow changes after a complete occlusion, whereas microdialysis detected changes earlier, and could detect both arterial and venous occlusion. Based on these results, the implantable Doppler probe for early detection of vascular occlusions cannot be recommended.

Highlights

  • Kidney transplantation improves survival rates in addition to improving health and quality of life in end stage renal failure[1,2,3]

  • In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex

  • Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow

Read more

Summary

Introduction

Kidney transplantation improves survival rates in addition to improving health and quality of life in end stage renal failure[1,2,3]. Access to kidney grafts is limited and early graft loss is potentially life threatening for the recipient. Vascular occlusions are rare, they still account for up to 35% of the grafts lost within the first 30 days after transplantation[4,5,6], and their elimination is crucial to improved outcomes[5,7,8,9]. Several risk factors for renal graft thrombosis have been identified. Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call