The thermal defects of A-150 plastic and graphite referenced to aluminium were determined for 800 keV protons scattered by a 2 mu m nickel foil (mean transmitted energy=550 keV). Composite cores of Al/A-150, graphite/A-150 and Al/graphite which could be irradiated from one side or the other were employed. The temperature increase of a core caused by 30-100 s of irradiation (3-6 nA of proton beam current) was detected by two thermistors mounted in opposite legs of a Wheatstone bridge. The thermal defect of A-150 plastic was determined to be 0.0421+or-0.0036 (SE) referenced to aluminium and 0.0402+or-0.0034 referenced to graphite. The thermal defect of graphite referenced to aluminium is 0.0043+or-0.0034. No change in the thermal defect of A-150 plastic was detected for accumulated doses up to 8*105 Gy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.