Abstract
In engineering pulse-jet dust collector applications, the filtration area and injection pressure are chosen mostly based on experience. The peak pressure is tested under different injection pressures and filtration areas controlled by an electromagnetic valve, and then comprehensively analyzes the effects of dust intensity, uniformity, and air consumption on dust cleaning to obtain a better filtration area controlled by an electromagnetic valve and injection pressure. The results show that considering the uniformity and intensity of dust cleaning, the filtration area of 33 m2 under the injection pressure of 0.4 MPa should be preferentially selected, with a standard deviation of 0.246 and a variance of 0.061. The filtration area of 27 m2 under the injection pressure of 0.3 MPa should be preferentially selected considering the unit air consumption, uniformity, and intensity of dust cleaning, the standard deviation of 0.252, and the variance of 0.064. The paper presents a theoretical foundation for selecting the optimal injection pressure and filter area regulated by an electromagnetic valve in pulse-jet dust collector systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.