Abstract

To use, existing critical care and early pandemic, data to inform care during the pandemic influenza A 2009 (H1N1) pandemic (with a possible use for triage - if the demand for critical care seriously exceeded supply). To monitor the impact of the H1N1 pandemic on critical care services, in real time, with regular feedback to critical care clinicians and other relevant jurisdictions to inform ongoing policy and practice. Modelling of data and cohort study. Modelling - 148 adult, general critical care units in England, Wales and Northern Ireland in the Intensive Care National Audit & Research Centre Case Mix Programme. Cohort study - 192 acute hospitals in England, Wales, Northern Ireland, Scotland and the Republic of Ireland. Modelling - 105,397 admissions to adult, general critical care units. Cohort study - 1728 H1N1 pandemic-related admissions referred and assessed as requiring critical care. Modelling - requirement for organ support and acute hospital mortality. Cohort study - survival to the end of critical care. Modelling - cancelled or postponed, elective or scheduled surgery resulted in savings in calendar days of critical, Level 3 and advanced respiratory care of 17, 11 and 10%, respectively. These savings varied across units. Using routine, physiological variables, the best triage models, for all and for acute respiratory admissions, achieved only satisfactory concordance of 0.79 and 0.75, respectively. Application of the best model on all admissions indicated that approximately 12.5% of calendar days of critical care could be saved. Cohort study - research governance approvals were achieved for 192 acute hospitals, for 91 within 1 day of central research and development approval across the five countries. A total of 1725 cases (562 confirmed) were reported. Confirmed cases were young (mean age of 40 years), had low severity of acute illness on presentation [61% CURB-65 (confusion, urea, respiratory rate, blood pressure, age over 65 years) 0-1], but had long stays in critical care (median 8.5 days) and were likely to be ventilated (77% for median 9 days). Risk factors for acute hospital death were similar to those for general critical care admissions. SwiFT was rapidly established. Models based on routine physiology suggested limited value for triage. More data and further modelling are warranted. The magnitude of the pandemic did not approach the worst-case scenario modelling, and UK-confirmed H1N1 cases appeared similar to those reported internationally. The National Institute for Health Research Health Technology Assessment programme.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call