Abstract

The cryomodule I for ADS Injection-I had been designed, fabricated and online tested. The CM1 contains seven superconducting magnets, seven superconducting spoke cavities and seven beam position monitors. The superconducting magnet, which is a kind of multifunction magnet in a 170mm length axial space, contains a solenoid for beam focusing and two correctors for orbit correction. The design goals for the magnets are to meet the required integral field strength and to reduce the leakage field of less than 2 G at the nearby superconducting spoke cavities. The 2.1K, 31 mbar cryogenic system, where the magnets and spoke cavities shared with, force the magnet must select a kind of conduction cooled current leads. The first one of the batch magnets was tested in a vertical Dewar in HIT in July, 2014. The measurement results met the design requirements. Online operation of CM1 in September, 2015 showed that seven magnets can work at 230A under 4.2K and 2.1K respectively. This paper will present the magnet and current lead design, field measurement and the installation progress.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.