Abstract

In the current laboratory investigation, the behavior of hollow circular concrete columns exposed to vertical compressive force is examined. The columns are externally strengthened with Glass Fibre Reinforced Polymer bars and textile fabric (one layer and two layers). The longitudinal reinforcement cast using concrete Reactive Powder Concrete has an outer diameter of (250 mm), a bore diameter of (100 mm), and a length of (1000 mm). The number of textile layers (one or two layers) is one of the main variables used in this experiment study. According to the experimental findings, the hollow circular concrete columns raised the tested concrete columns' bearing capacities by roughly (9.93%) and (17.8%), respectively, after the specimens were allowed to cure for 28 days. This improvement was made for strengthening columns that were subjected to compressive loads and had one or two layers of textile fabric.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.