Abstract
Longitudinal recording media made with chromium and with nickel-aluminum underlayers are compared. NiAl films have smaller grains and random crystallographic orientation, while Cr films have larger grains and either a {110} or a {200} preferred orientation depending on the deposition conditions. Cobalt alloy films grown on NiAl have nearly random crystallographic orientation and significant c-axis out-of-plane component, and lower hysteresis loop squareness and coercivity than films made on a heated Cr underlayer. NiAl-underlayer media do not exhibit in-plane magnetic anisotropy induced by the substrate texture lines. CoCrTaPt/Cr/NiAl media had higher overwrite than CoCrTaPt/Cr media due to higher coercive squareness and a sharper hysteresis loop closure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.