Abstract

Background. The development of effective methods for diagnosing multicentric breast cancer patients (BC) is of great clinical importance, because it determines the tactics of surgical and radiation treatment. The aim of study: to compare diagnostic accuracy of scintimammography (SMG), digital mammography (MMG) and ultrasound (US) in the diagnosis of multicentric BC. Materials and methods . 410 women with histologically confirmed BC were included in this analysis. SMG was performed with dual detector SPECT unit Forte (Philips, Netherlands). Mammographic digital images were obtained on Senographe DS unit (GE Healthcare, USA). In 319 of 410 evaluated women we were able to determine results of preoperative US with high-frequency (7—18 MHz), high resolution linear array transducer. The pathological report was used as the gold standard. Multicentric BC was defined as 2 or more distinct invasive tumors occupying more than one quadrant. Detection of additional grouped calcifications of malignant type occupying a small portion of breast tissue (more than 15 pieces per 1 sq. cm) was considered as another mammographic sign of multicentric BC. Results. According to histopathological examinations multicentric BC was diagnosed in 51 of 410patients. SMG was more effective than MMG in detecting multicentric BC: sensitivity — 84.3 % vs 54.9 % (p <0.001), specificity — 98 % vs 95.8 % (p = 0.02), accuracy — 96.3 % vs 90.7 % (p = 0.04), positive and negative predictive values — 86 % vs 65.1 % (p = 0.004) and 97.8 % vs 93.7 % (p = 0.01), respectively. Histologically multicentric BC was revealed in 44 of 319 women that had US of the breasts. Sensitivity, specificity, accuracy, positive and negative predictive values for US were 52.3 %, 94.5 %, 88.7 %, 60.5 % and 92.5 %, respectively. SMG significantly (p <0.001) outperformed US for all diagnostic characteristics. Combination of MMG and SMG characterized by increased sensitivity (94.1 %), 94.2 % specificity, 94.1 % accuracy and positive predictive value of only 69,6 %. Conclusions. SMG is significantly more sensitive (84.3 %) than MMG (54.9 %) and US (52.3 %) in detection of multicentric BC. High (86 %) positive predictive value of SMG advocates it as a tool for surgery and radiotherapy planning.

Highlights

  • The development of effective methods for diagnosing multicentric breast cancer patients (BC) is of great clinical importance, because it determines the tactics of surgical and radiation treatment.ОПУХОЛИ ЖЕНСКОЙ РЕПРОДУКТИВНОЙ СИСТЕМЫ Оригинальные статьи TUMORS OF FEMALE REPRODUCTIVE SYSTEM4 ’2019 Том 15 / Vol 15The aim of study: to compare diagnostic accuracy of scintimammography (SMG), digital mammography (MMG) and ultrasound (US) in the diagnosis of multicentric BC

  • Materials and methods. 410 women with histologically confirmed BC were included in this analysis

  • Multicentric BC was defined as 2 or more distinct invasive tumors occupying more than one quadrant

Read more

Summary

Оригинальные статьи

И ультразвукового исследования в диагностике мультицентричного рака молочной железы. Цель исследования – сравнить диагностические возможности маммосцинтиграфии (МСГ), цифровой маммографии (ММГ) и ультразвукового исследования (УЗИ) в диагностике мультицентричного РМЖ. МСГ была эффективнее ММГ при выявлении мультицентричного РМЖ – ее чувствительность составила 84,3 % против 54,9 % (p

Background
CC г е
Findings
Dense scintimammography
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have