Abstract

Objective To compare the efficiency of breast specific gamma imaging (BSGI) and mammography for the diagnosis of breast carcinoma.Methods Fifty-six patients suspected of breast carcinoma underwent both BSGI and mammography within 15 d interval before surgery,and the diagnostic results were verified with histological examination.The sensitivity,specificity,accuracy,positive predictive value and negative predictive value were calculated.x2 test was applied for statistical analysis.Results The sensitivity,specificity,accuracy,positive predictive value,negative predictive value of BSGI and mammography were 92%(34/37) vs 76%(28/37),84%(16/19) vs 74%(14/19),89%(50/56) vs 75%(42/56),92%(34/37) vs 85%(28/33),84%(16/19) vs 61%(14/23),respectively,and there was no significant difference between the two methods (x2 =1.14,P>0.05).There were 6 breast carcinoma patients with dense breast tissue,and those malignant lesions were accurately identified with BSGI,but not with mammography.Conclusion BSGI is a useful adjunct imaging modality for the diagnosis of breast carcinoma,especially for the dense breast. Key words: Breast neoplasms; Radionuclide imaging; Mammography; Diagnosis, differential

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.