Abstract
AbstractWater disinfection by indirect plasma treatment was investigated using a surface dielectric barrier discharge (DBD). Liquid was neither part of the discharge electrode configuration nor stirred during plasma treatment. High concentrations (106–108 cfu·mL−1) of Escherichia coli and Staphylococcus aureus have been completely inactivated within 5–15 min, depending on liquid sample volume. Inactivation occurred in non‐buffered liquids, only, where pH decrease was found. Measurements of pH, nitrate, and nitrite concentrations after DBD plasma or NO gas treatment lead to the conclusion that nitric acid formation from plasma‐generated reactive nitrogen species are the main source of liquid acidification. Incubation of bacteria in nitric acid alone did not result in comparable inactivation effects. Increase of H2O2 concentration was found as a result of plasma treatment of liquids but not after treatment by NO gas. Therefore, synergistic action of both reactive oxygen and nitrogen species are discussed to be responsible for antimicrobial plasma effects.magnified image
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.