Abstract
Multicenter retrospective cohort study. To evaluate the efficacy and safety of using cement-augmented pedicle screw (CAPS) fixation only for the cephalad and caudal vertebral bodies. Pedicle screw fixation is less effective in patients with low-quality bone. Although CAPS fixation has shown promise in improving stability and reducing screw loosening in such cases, cement leakage can have serious consequences. This study included 65 patients who underwent spinal surgery using CAPS and were followed up for >3 months. Four CAPSs were used in each patient, and 254 CAPSs were included in the analysis. Of the 65 patients, 36.9% showed intravenous cement leakage, and a low bone mineral density (BMD) was associated with a higher risk of cement leakage. The use of a CAPS on the right side was also potentially associated with a higher risk of leakage. However, the shape and location of the leaked cement remained stable over time. Screw loosening occurred in 3.5% of the CAPSs and was associated with a lower cement volume. Cement leakage was related to lower BMD. Using CAPS exclusively at the lower or upper instrumentation levels might minimize the risk of cement leakage in osteoporotic patients.