Abstract

The hot summer and cold winter zone in China belong to the non-central heating area. In recent years, with the improvement of people’s living standards, more and more residential building have begun to adopt various heating methods. However, many existing buildings have poor air tightness level, and the indoor thermal environment is in a bad condition, which also causes a great waste of energy. Based on the actual measurement of the airtightness of a demonstration building, this paper studies the effects of residential airtightness on heating and air conditioning energy consumption and indoor thermal environment in winter. The simulation results show that in the hot summer and cold winter zone, the level of air tightness also influence the heating and air conditioning energy consumption, but the impact on heating energy consumption is more obvious. In addition, when selecting energy-saving measures, the relationship between the level of air tightness and the level of insulation should be weighed. We should not reduce energy consumption only by improving the airtightness level. Otherwise, the investment is large and the energy saving effect is very poor.