Abstract

It is assumed that the width of the optic nerve sheath diameter (ONSD) is dependent on intracranial pressure (ICP) and pulsatility and thus constitutes a non-invasively accessible "window" for qualitative assessment of ICP. Data on the correlation to invasively measured ICP in children are scarce and have often been obtained from sedated patients in intensive care unit (ICU) or intraoperatively. We report on a mixed cohort of pediatric neurosurgical patients, ICP and ONSD measurements were available from both sedated and awake children, only a minority from ICU patients. Seventy-two children were investigated. Ultrasound ONSD determination was performed immediately prior to invasive ICP measurement and the mean binocular ONSD was compared with ICP. The investigations were performed in children awake, sedated, or under general anesthesia. In the entire patient cohort, the correlation between ONSD and ICP was good (r = 0.52, p < 0.01). Children > 1year revealed a better correlation (r = 0.63; p < 0.01) and those ≤ 1year did worse (r = 0.21). Infants with open fontanelle had no correlation. In the entire cohort, the best ONSD cut-off value for detecting ICP ≥ 15 and ≥ 20mmHg was 5.28 and 5.57mm (OR 22.5 and 7.2, AUC 0.782 and 0.733). Transorbital ultrasound measurement of ONSD is a reliable non-invasive technique to assess increased ICP in children in every clinical situation; however, the impact of age and fontanelle status needs to be considered. ONSD thresholds enable qualitative first orientation regarding ICP categories with a very satisfying diagnostic accuracy.