Abstract
Two methods are presented for reducing the magnitude of the propagated pressure waves resulting from the reduction of flow in a reservoir-valve-pipe system. The theoretical performances of the two methods are investigated and compared with a third method developed by Streeter (1)†, and with that resulting from simple linear closure of the valve controlling the flow. The two methods indicate a maximum reduction of around 80 per cent in the magnitude of the pressure wave, and a significant reduction for valve closure in one pipe period.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.