Abstract

Albino rats were used to determine the effects of the reapplication of microvascular clamps in veins after anastomosis. The results demonstrate that, if necessary, microvascular clamps can be reapplied either proximal, or both proximal and distal to a venous anastomosis for up to 30 minutes, thus allowing a suture to be redone or the lumen to be explored with no loss of patency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.