Abstract

Preoperative diagnosis of periprosthetic shoulder infections (PSI) is difficult. Infections are mostly caused by low virulence bacteria and patients do not show typical signs of infection. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination with multiplex polymerase chain reaction (mPCR), serum markers, and/or synovial markers for the preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. A prospective explorative diagnostic cohort study was performed including 55 patients undergoing revision shoulder replacement surgery. A shoulder puncture was performed preoperatively before incision to collect synovial fluid for mPCR analysis and for measurement of interleukin-6, calprotectin, white blood cell count (WBC), and polymorphonuclear cells. Also prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two for mPCR analysis. A blood sample was obtained to determine serum C-reactive protein, WBC, and erythrocyte sedimentation rate. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; the primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, blood and synovial markers, mPCR, and combinations thereof. Routine tissue cultures were positive for infection in 24 patients. Cultures from ultrasound-guided biopsies diagnosed infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. The best diagnostic value was found for the combination of ultrasound-guided biopsies for culture, synovial WBC, and calprotectin with a sensitivity of 69.2%, specificity of 80.0%, PPV of 69.2%, and NPV of 80.0%. Ultrasound-guided biopsies for cultures alone and in combination with mPCR, and/or blood and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of PSI. Diagnostic study level II.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.