Abstract

Liquid-liquid extractions of acetic acid from acetic acid-methyl isobutyl ketone solution by means of water were studied in a pulsed perforated-plate column. Holdup of dispersed ketone phase and transfer rate of acetic acid, from which (HTU) oe was calculated, were measured, and the performance characteristics of pulsed perforated-plate column based on the variation of holdup with the pulsed velocity was studied.Three operation regions are defined from plots of holdup versus pulsed velocity of various conditions. Holdupcurves are divided into three parts; the mixer-settler region where holdup decreases with increasing pulsed velocity; transition region where holdup increases slowly; emulsion region where holdup increases abrubtly.(HTU) oe decreases with increasing pulsed velocity in the mixer-settler and transition regions, and increases in the emulsion region. Therefore, the minimum value of (HTU) oe is obtained at the boundary point between the transition and emulsion regions.The amf value at the two boundary points, holdup in the three operation regions and (HTU) oe in the two operation regions were correlated as experimental equations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.