Abstract

This paper proposed the Weighted Least Square method (WLS method) to identify the output filter of three-phase PWM converter, which incorporates the signal processing as well as mathematical techniques into conventional Least Square method. It sets different weights to different measurements according to the phase where it locates, based on the discovery of the correlation between accuracy and phase of current. The algorithm is tested in both simulation and experimental environment, and the results validate that proposed method gives accurate estimation in steady state, and can response within 10ms in when grid voltage drops. This method can work under both balanced and unbalanced operating conditions, therefore provides a powerful tool for various control strategies to better understand the operating conditions. Compared with the invasive method, which intentionally inject a series of white noise in the system, proposed WLS method does not bring any turbulence, while compared with conventional Least Square method, it possesses better stability as well as higher accuracy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.