Abstract
A laboratory distillation column is to be set up to evaluate overall column efficiencies at finite reflux. The choice of the number of plates in each section of the column will profoundly affect the accuracy of the final results. That number of plates which minimises the errors is optimal. A general analysis of the contribution of experimental errors to errors in the final results is presented. It is applied to the evaluation of the optimal number of “theoretical” plates for the test system methycyclohexane-toluene over a range of internal reflux ratio 0·7 to 1·00 in the rectifying section and 1·00 to 1·30 in the stripping section. The author's experimental results with the above test system in a 1 1 4 in. Oldershaw column are used to provide the necessary overall efficiencies for a design calculation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.