Abstract

BackgroundChildren with cerebral palsy (CP) make smaller medio-lateral anticipatory postural adjustments (APAs) than typically developing peers when stepping forward to a medial target. They are also less accurate at reaching the stepping target.The Next Step test involves the biomechanical measurement of APAs and foot placement error. These may be useful outcome measures to evaluate dynamic balance in a clinical trial. The reliability of the measures must be assessed to establish their reliability as research tools. Research questionWhat is the inter-rater and intra-rater reliability of stepping accuracy and measures of APAs made by children prior to taking a step? MethodsTypically developing (TD) (n = 14) or children with CP (n = 16) were recruited from local clinics. Children stepped to electro-luminescent targets placed medially and laterally to each foot. Stepping responses were measured using a force plate and 3D motion analysis of markers placed on the feet and pelvis. The APA was defined as the movement of the centre of pressure (COP) and the centre of mass (COM) estimated via pelvic markers, prior to lifting the lead leg. Stepping accuracy was defined as the absolute distance between the target and end foot position. Participants undertook two data collection sessions separated by at least one week. In session one, the test was measured by rater 1 who repeated this in session two, along with another data collection by a rater 2 or rater 3, after a rest period. Where data were normally distributed, they were assessed for inter-rater and intra-rater reliability using an intra-class correlation coefficient (ICC) and Bland-Altman plots. The standard error of measurement was calculated to determine the minimum difference needed to detect true change. ResultsThere was no between-group differences in group characteristics (age, weight, height) or in stepping velocity. We found good to excellent reliability when measuring the amplitude and velocity of medio-lateral APAs (ICC range 0.73–0.89). The reliability of antero-posterior APAs was more variable (ICC range 0.08–0.92). The minimum difference to detect a true change for peak medio-lateral motion of COP ranges from 23.7 mm to 29.6 mm and for peak velocity of medio-lateral COM estimate 41–61.9 mm. Stepping accuracy was not normally distributed. SignificanceThe Next Step test is a reliable measure of dynamic balance. The peak medio-lateral motion of the COP and medio-lateral velocity of the COM estimate are reliable when measured during a constrained stepping task in ambulant children with cerebral palsy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.