Abstract

The paper describes the modification of the SRG-50-751 connector by means of the support bead material change. The modification is made in order to extend the operating temperature range of the connector, and may also reduce the VSWR of the connector. The modified coaxial quarter-wavelength resonator method is used for bead parameter control. The modification of the method increases the dielectric constant measurement accuracy and enables to measure specimens with different lengths. The method of dielectric loss tangent measurement of the beads is outlined in the article.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.