Abstract

The microdosimetric one-hit detector model has been developed and applied to calculate the dose response, energy response and relative efficiency of thermoluminescent LiF:Mg,Cu,P and CaF 2:Tm detectors, and of the free-radical alanine dosimeter, after their exposure to radiation of different quality. The one-hit detector is described by two model parameters: the target diameter, d and the saturation parameter, α. Combining these parameters with microdosimetric distributions in nanometer-size targets calculated using Monte Carlo track structure codes TRION and MOCA-14, it was possible to describe and predict a great variety of experimental data for photon, X-ray, beta-electron, proton, alpha-particles and heavy ion irradiation. Within the framework of this biophysical model of radiation action, some mechanistic insight into the physics of radiation action in solid state detectors can be obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.