Abstract

We have compared the effect of locking and grasping suture loop configurations in four-strand core suture techniques for tendon repair. Forty canine flexor digitorum profundus tendons were repaired with one of four suture techniques (the grasping cruciate, the double-modified grasping Kessler, the locking cruciate and the double-modified locking Kessler) and tested to failure in a tensile testing machine. The mode of failure in all the locking suture specimens was breakage of the sutures in the locking loops or at suture knots. The sutures did not pull out of the tendon, as was seen in the grasping suture specimens. The greatest tensile strength was found with the double-modified locking Kessler technique which incorporated eight rectangular locking loop configurations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.