Through the characteristics of the Impulse electro flotation Wastewater treatment equipment, the factors which affect the efficiency of this technology are analyzed. According to the Kinematical theory of flocculation process, the free particle flotation removal model is established used in the way how the steel ball model is simplified. , and the variable process of the concentration of the free particle along with the time is stimulated to be obtained. This mathematical model has the theoretical reason of how to choose the electric flotation parameters and design of the electric flotation treatment equipments. The result proves that when the treatment time is between 20 to 25 min., the removal rate of the free particles will achieve to above 90%, which is similar to the experiment data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.