Abstract

The KVI is conducting radiobiology research using protons up to 190MeV from the superconducting AGOR cyclotron in collaboration with the University Medical Center Groningen (UMCG) since 1998. Using the same set-up, we have started irradiations for radiation hardness studies of detectors and components for the European Space Agency (ESA) and industrial parties. For these irradiations, we use either mono-energetic protons or a simulated solar flare energy spectrum with fluxes up to 5×108protonscm−2s−1. Furthermore, tests of radiation effects such as single event upsets, are being performed with intensities down to a few particles/s. Different energies are achieved by degrading the primary beam energy. We are currently developing the capability for heavy ion irradiations in air with beams up to Xe at beam energies between 15 and 45MeV per nucleon. Performing the irradiations in air simplifies handling and monitoring of the device under test. The high energy allows penetration to the active layer of electronic devices, without modifications to the chip housing. The different ions provide a wide range in LET.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call