Abstract

BackgroundCardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images. We sought to determine whether magnetic field strength affects the intra-observer reproducibility of CMR-FT strain analysis. MethodsWe studied 2 groups, each consisting of 10 healthy subjects, at 1.5T or 3T Analysis was performed at baseline and after 4 weeks using dedicated CMR-FT prototype software (Tomtec, Germany) to analyze standard SSFP cine images. Right ventricular (RV) and left ventricular (LV) longitudinal strain (EllRV and EllLV) and LV long-axis radial strain (ErrLAX) were derived from the 4-chamber cine, and LV short-axis circumferential and radial strains (EccSAX, ErrSAX) from the short-axis orientation. Strain parameters were assessed together with LV ejection fraction (EF) and volumes. Intra-observer reproducibility was determined by comparing the first and the second analysis in both groups. ResultsIn all volunteers resting strain parameters were successfully derived from the SSFP images. There was no difference in strain parameters, volumes and EF between field strengths (p>0.05). In general EccSAX was the most reproducible strain parameter as determined by the coefficient of variation (CV) at 1.5T (CV 13.3% and 46% global and segmental respectively) and 3T (CV 17.2% and 31.1% global and segmental respectively). The least reproducible parameter was EllRV (CV 1.5T 28.7% and 53.2%; 3T 43.5% and 63.3% global and segmental respectively). ConclusionsCMR-FT results are similar with reasonable intra-observer reproducibility in different groups of volunteers at 1.5T and 3T. CMR-FT is a promising novel technique and our data indicate that results might be transferable between field strengths. However there is a considerable amount of segmental variability indicating that further refinements are needed before CMR-FT can be fully established in clinical routine for quantitative assessment of wall mechanics and strain.

Highlights

  • Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images

  • The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength

  • In all volunteers resting strain parameters were successfully derived from the SSFP images

Read more

Summary

Open Access

Andreas Schuster1,2*, Geraint Morton, Shazia T Hussain, Roy Jogiya, Shelby Kutty, Kaleab N Asrress, Marcus R Makowski, Boris Bigalke, Divaka Perera, Philipp B Beerbaum, Eike Nagel. From 16th Annual SCMR Scientific Sessions San Francisco, CA, USA. From 16th Annual SCMR Scientific Sessions San Francisco, CA, USA. 31 January - 3 February 2013

Background
Methods
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.