Abstract
Vestibular-evoked myogenic potentials (VEMPs) are proposed as a reliable test to supplement the current vestibular test battery by providing diagnostic information about saccular and/or inferior vestibular nerve function. VEMPs are short-latency electromyograms (EMGs) evoked by high-level acoustic stimuli and recorded from surface electrodes over the tonically contracted sternocleidomastoid muscle. VEMP amplitude is influenced by the EMG level, which must be controlled. This study examined the ability of subjects to achieve the EMG target levels over a range of target levels typically used during VEMP recordings. In addition, the influence of target EMG level on the latency and amplitude of the click- and tone-evoked VEMP was examined. The VEMP amplitude increased as a function of EMG target level, and the latency remained constant. EMG target levels ranging from 30 microV to 50 microV are suggested for clinical application of the VEMP.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of Rehabilitation Research and Development
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.