The paper presents an experimental investigation of the influence of thread length and tightening torque of the M8 and M12 bolts on the vibration fixture response. To perform the tests electromagnetic vibration exciter with amplifier (LDS V8900), controller (M+P), single-axis control and measurement accelerometer (PCB), and calibrated dynamometric key (Hazet) were used. As vibration profile was used sinusoidal on a linear scale amplitude (g2) versus time (Hertz) according to the IEC 60068-2-6 standard. To investigate the length and diameter of the bolts aluminum 7075 T6 fixtures with dimensions of 40 mm ´ 40 mm width and different lengths were used as part of the samples. It was found that the investigated parameters have a major influence on the vibration fixture response.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.