Abstract

The application of two-phase slug flows for extraction processes in micro capillaries was investigated and the mass transfer performance under different conditions was analysed. As contacting capillaries PTFE or FEP tubes were used with internal diameters ranging from 0.5mm to 1mm. Two extraction systems were experimentally tested for the evaluation and the extraction efficiencies were measured for various flow rates and slug lengths. In the experiments the slug length was manipulated at a constant flow rate by means of a specially developed slug valve and a complete separation was ensured by a newly designed robust phase separator. Besides single-step experiments, a counter-current microfluidic flow was realised by connecting co-current flow modules in a counter-current arrangement and performance results for a two-stage counter-current operation were also obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.