Abstract

Fluorescent lamps were once used as standard noise sources for microwave measurements. Because of unpredictable noise output, they were abandoned in favor of pure-gas discharge tubes. It is shown that the unpredictability resulted from changes in Hg vapor pressure which were indirectly caused by cataphoretic pumping of the Hg ions. Data are presented which give excess noise as a function of discharge current and as a function of bulb temperature. These data were obtained for normal and abnormal lamps at 147 MHz.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.