Abstract

In order to study the influence factors of complex three-dimensional electrode polarity to treat phenol wastewater .Set the mixed phenol wastewater as the research object, by the test of static, adopt complex three-ensional electrode polarity to phenol wastewater. When the wastewater is 10 L,quality concentration is 300 mg/L, the pH value is 3.0, the reaction time is 90 min, electrolytic voltage is 15V, plate spacing is 10 cm, Na2SO4 electrolyte additive concentration is 1 g/L, Fe2+ additive concentration is 0.6 mmol/L, aeration intensity is 0.2 m3/h, removal rate of phenol and COD reached 80.99% and 80.99% respectively . The experiments results show that the pH value, reaction time, electrolytic voltage, plate spacing and aeration intensity has a significant effects on phenol wastewater through complex three-dimensional electrode polarity treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.