Abstract
The paper presents the results of tests of the wear of cutting tools following the process of facing with lubrication with cutting fluids. The tests were carried out on a CNC lathe with the use of two cutting fluids: one based on mineral oil and the other containing zinc aspartate. After machining, the tool wear was measured using a stereoscopic inspection microscope. Observation of surface morphology and identification of elements was performed using a scanning electron microscope with a EDS analyser. Measurements of the geometric structure of the surface of turned elements were performed using an optical profilometer. The non-toxic coolant with zinc aspartate used in the tests resulted in the formation of surface layers enriched with zinc compounds, which directly translated into the improvement of technological quality of the workpiece.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.