Abstract

The improvement and verification of fluid dynamics simulation on temperature uniformity during the heat treatment of ring pieces are investigated in this study. The accuracy of the temperature field model is validated by comparing the simulation results with the measured temperatures. The findings reveal that the vortex generated near the furnace wall during heat treatment significantly affects the uniformity of the temperature field. To improve this, adjustments are made to the placement of ring pieces based on an experimentally validated fluid dynamics simulation model, and subsequent calculations are performed on this adjusted model. It is observed that these adjustments greatly enhance temperature uniformity in the heating process, with a 39.06 % improvement in medium-temperature zone (732.32–743.69 k) within the furnace compared to the original model. Additionally, surface temperatures of ring pieces in another medium-temperature zone (668.89–691.11 k) show a 34.54 % improvement in comparison to those predicted by the original model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.