The purpose of this paper is to present the importance of the specific tests for electric motors with type of protection increased safety „e” designed to be used in explosive atmosphere. This paper presents the voltage impulse ignition test applicable to electric motors with increased safety protection type. Due to the fact that electric motors with type of protection Increased Safety, whose supply voltage exceeds 1000 V, presents a high risk of sparks occurring in windings, it is necessary to perform tests to verify that the insulation of the windings is adequate and does not lead to electric discharge (through electric springs or sparks) at winding levels Evaluation of explosion-proof protected electrical equipment in scope of certification is extremely important considering the risk of explosion that has to be minimized in order to ensure life safety and health of workers and to prevent damaging of property and the environment, as well as free movement of goods when they meet the essential safety requirements at European level. The standard SR EN 60079-0 (Explosive atmospheres Part 0: General requirements) and one or more of the standards containing the specific requirements for the type(s) of protection applied to equipment (ex. SR EN 60079-7 for the type of protection increased safety “e”), are used to perform the assessment.