Abstract
This study investigated heat transfer and friction characteristics in a forced convection system using wavy twisted tape inserts with circular holes. The inserts, with twist ratios (TR) of 8.5, 7.5, and 6.5, were placed inside a test pipe to create turbulent flow. The tapes measured 700 mm in length and 18 mm in width, while the test pipe had an outer diameter of 35 mm and an inner diameter of 30 mm, with a test section length of 700 mm. Airflow rates were adjusted to achieve different bulk mean temperatures. Experimental data were used to develop new correlations for the Nusselt number and friction factor. The Reynolds number (Re) ranged from 4,000 to 14,000. Comparisons between the wavy twisted tape inserts with varying twist ratios and pitches and a smooth tube showed that the highest heat transfer rate was achieved with a twist ratio of 6.5.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have