Abstract

An RLC meter was used to measure the inductances and capacitances of both plastic quad flat package (PQFP) and plastic ball grid array (PBGA) with test chips inside the packages. A test chip was used to simulate the real package condition, although the standard measurement guideline such as EIA/JED123 does not include it. Combining test chip layout, test ground fixture and grounding technique, the complex n-lead model could be simplified into a one-lead model which leads to obtain the inductance or capacitance of pins in a package easily. Two kinds of packages PQFP and PBGA were investigated, each one had five samples which were measured from 0 to 3GHz range. From the inductance/ capacitance versus frequency curves, the frequency limitation of packages is obtained. The average inductance values per mm for both PQFP and PBGA are 0.99±0.05 nH/mm and 0.95±0.05 nH/mm, respectively, while the average capacitance values for PQFP and PBGA are 0.89±0.02 pF and 0.79±0.02 pF as relating to each.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.