Abstract

Monitoring aerobic exercise intensities of free-living physical activities is valuable for purposes such as education and research. The heart rate (HR) method, based on the linear relation between HR and oxygen uptake (VO2), is potentially valuable for this purpose. Three prerequisites are that the method is reproducible, and valid for the specific form of physical activity executed as well as under field conditions. The aim of this study is to evaluate reproducibility of the heart rate method in the laboratory. VO2 and HR measurements were made on two different occasions during three submaximal (model 1) plus a maximal exercise intensity (model 2) on a cycle ergometer in the laboratory. 19 habitual commuter cyclists (9 males and 10 females), aged 44 ± 3 years, were measured. The reproducibility of the estimated VO2, based on three levels of HR from commuting cycling and the regression equations from test and retest were analyzed. Differences between the two models were also studied. For both models, there were no significant differences between test and retest in the constituents of the regression equations (y-intercept, slope and r-value). Neither were there any systematic differences in estimated absolute levels of VO2 between test and retest. The relative differences between test and retest, based on estimations from three different levels of HR, were 0.99 ± 11.0 (n.s.), 2.67 ± 6.48 (n.s.) and 3.57 ± 6.24% (p<0.05) for model 1, and 1.09 ± 10.6, 1.75 ± 6.43 and 2.12 ± 5.92% (all n.s.) for model 2. However, some large individual differences were seen in both models. There were no significant differences between the two models in the slopes, intercepts or r-values of the regression equations or in the estimated levels of VO2. The heart rate method shows good reproducibility on the group level in estimating oxygen consumption from HR-VO2 relations in the laboratory, and based on three levels of HR which are representative for cycle commuting. However, on the individual level, some large variations were seen.

Highlights

  • Monitoring metabolic demands and physiological work intensities of physical activities in field conditions is of great value in e.g. education and research

  • An important feature of this study is that we have developed a transparent framework for analyses of the reproducibility of the heart rate (HR) method in laboratory conditions

  • It is characterized by positioning all HR values used in relation to both resting and maximal HR

Read more

Summary

Objectives

The aim of this study is to evaluate reproducibility of the heart rate method in the laboratory. The aim of the study was to evaluate day-to-day reproducibility of HR-VO2 regression equations (y-intercept, slope and correlation coefficient) and the estimated oxygen uptakes based on three levels of heart rates representative for everyday cycle commuting

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call