Abstract

Several automatic focusing approaches have been proposed in the past to compute the refocus distance in digital holography (DH) and digital holographic microscopy (DHM). Most of the automatic focusing approaches are in combination with the convolution or angular spectrum method as numerical reconstruction algorithms for digital hologram. Relatively little work has been done on the combination of detecting the focus distance by automatic focusing approaches with Fresnel transform based method for digital holographic reconstruction. In this letter, the feasibility and application of the Fresnel transform based method to perform a digital holographic reconstruction in automatic focusing in DH are studied. The numerical simulation and experimental results are given. The results validate that the Fresnel transform based reconstruction algorithm can also be effectively applied to automatic focusing in DH and DHM.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.