Abstract
The fatigue lifetimes and fractography were compared for nickel and typical nickel base alloys of the Monel, Inconel, and Incoloy series, tested at room temperature in alternating tension in the environments of air and liquid mercury. It was found that the fatigue life was always less in mercury and that a different fracture mode resulted. The alloys Nickel 200, Inconel 600, Incoloy 800, and Incoloy 825 that did not show intergranular fractures in the slow strain-rate tensile tests, did so under fatigue testing. A generalized crack propagation sequence in mercury was identified beginning with intergranular cracking but transferring eventually to transgranular modes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.