Abstract
Along with the rapid development of electric power industry in China, the pollutant discharge limits are getting more strict, and WFGD (wet flue gas desulfurization) technology and its equipment have been greatly developed and extensively applied, in which the gas-gas heater (GGH) is adopted at lots of the power stations. The corrosion is a very important issue in GGH, and it is experimentally studied in this paper. Through experiment of polarization curves and the control variable method, a comparative analysis of the corrosion resistance between the commonly used materials of the GGH is made. The results have shown that the corrosion resistance with the heat transfer surface in GGH will decrease with the temperature increasing, but the enamel steel’s corrosion resistance and stability is strikingly better than that of others, and the increasing volume of corrosion resistance by plating enamel is remarkable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.