Abstract

The experimental investigation of natural convection analysis in pressurized containers has been successfully addressed fusing four identical circular rectangle pipes. The pressurized tank of 0.3 m diameter and 0.45 m height within 0.43 m height and 0.025 m side length interior square pipes are used to obtain the present investigation. Various parameters are used such as gauge pressure (0.5-1 bar), pipes Ra configurations and enclosure orientations. The results are Nusselt number for cold and hot sides. Both sides has reverse response, the parametric analysis shows the ordinary behavior according to gravity and pressure forces interaction. The optimum conditions is observed when horizontal enclosure of top pipe in one bar is applied where the heat transfer improvement is 24 % approximately.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.