Abstract
An investigation of the use of ultrasonic agitation for cleaning printed circuit boards using CFC‐based solvents has shown that, under the standard conditions required to produce clean assemblies, no damage will occur to the components studied. Damage can only be induced by use of anomalously longer times or higher power densities. In all cases in which damage has been induced, it is of a purely mechanical nature due to fatigue, and is located on the device bond‐wires and/or the package legs. Cleaning using CFC‐based solvents under standard ultrasonic conditions of power density and time etc. is readily achieved within 2 minutes, even with a minimum stand‐off height.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.