Abstract

We have performed a picosecond ultrasonic study of the effects of oxygen partial pressure on the acoustic velocity in zirconium oxide films made by radio frequency reactive sputtering. To derive more accurate and reliable values of sound velocity, various reflective layers were used to enhance the echo signals of acoustic pulses photoexcited by an ultrafast laser. It is found that the acoustic responses of the samples with a W reflective layer are much stronger than those with a Si or SiO 2 reflective layer. In addition, the W reflective layer generates extra photoacoustic waves, which can be utilized to improve the accuracy of velocity measurement. The thin film velocities we measured were 10∼24% less than the bulk value, and exhibited a strong dependence on the growth conditions and the microstructure of films.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.