Abstract

Artery buckling occurs due to hypertensive lumen pressure or reduced axial tension and other pathological conditions. Since arteries in vivo often experience axial twisting and the collagen fiber alignment in the arterial wall may become nonsymmetric, it is imperative to know how axial twisting and nonsymmetric collagen alignment would affect the buckling behavior of arteries. To this end, the objective of this study was to determine the effect of axial twisting and nonsymmetric collagen fiber distribution on the critical pressure of arterial bent buckling. The buckling model analysis was generalized to incorporate an axial twist angle and nonsymmetric fiber alignment. The effect of axial twisting on the critical pressure was simulated and experimentally tested in a group of porcine carotid arteries. Our results showed that axial twisting tends to reduce the critical pressure depending on the axial stretch ratio and twist angle. In addition, nonsymmetric fiber alignment reduces the critical pressure. Experimental results confirmed that a twist angle of 90° reduces the critical pressure significantly (p < 0.05). It was concluded that axial twisting and non-axisymmetric collagen fibers distribution could make arteries prone to bent buckling. These results enrich our understanding of artery buckling and vessel tortuosity. The model analysis and results could also be applicable to other fiber reinforced tubes under lumen pressure and axial twisting.