Abstract

This paper presents the experimental study on the effectiveness of combined gripping method employed in the tensile testing of UHMWPE (Dyneema® SK75) single yarn. Seven different solutions including epoxy, acrylic, and ethyl cyanoacrylate adhesives were tested under quasi-static loadings in order to determine the most effective adhesive for bonding UHMWPE single yarn to aluminium sheets. The ethyl cyanoacrylate adhesive combined with polyolefin surface primer was found to be the best choice which could prevent yarn slippage and ensure the failure of yarn occurs in the gauge section. The single yarns were then tested at three strain rates of 3.3×10-5, 3.3×10-3, and 0.33 s-1. The tensile strength, maximum strain, and Young's modulus were determined from the measured stress-strain curves and compared with the values from literature; the results showed these tensile properties of single yarn depend on strain rate over the range tested.